CHEMIS server
Parameters
Parameter | Datatype | Default Value | Description |
---|---|---|---|
DEBUG | enum | 0 | Enable debugging |
DUMP | enum | 0 | Enable communication dump |
INACTIVITY_TIMEOUT | float | 30 | Rx inactivity timeout [s] |
HOST | hostname | 0.0.0.0 | Listen hostname or address (0.0.0.0 = any) |
PORT | integer | 25000 | Listen port |
CONNECTION_LIMIT | integer | 0 | Maximum number of simultaneous connections (0 = no limit) |
ADDRESS_FALLBACK | enum | 0 | Use communication object name when provider address is not present |
Measurements
This stack supports measurements.
Measurement address
Type: regex
Description:
Signal name to be presented to the client, will be left-padded to 7 characters by spaces
Examples:
3UA1001
4UR2003
3SS1024
Commands
Commands are not supported on this stack